Price 1700 INR/ Piece

MOQ : 1 Piece

Flow Sensor For Savina Specification

  • Weight
  • 100 Grams (g)
  • Resistance
  • <10
  • Output
  • Analog Voltage
  • Theory
  • Thermal/Differential Pressure Principle
  • Type
  • Differential Pressure Flow Sensor
  • Accuracy
  • 2% full scale
  • Operating Voltage
  • 5V DC
  • Output Voltage
  • 0 to 5V
  • Compensated Temperature
  • 0C to 50C
  • Storage Temperature
  • -20C to 70C
  • Operating Temperature
  • 0C to 60C
  • Flow Range
  • 0 to 80 L/min
  • Humidity Range
  • 0-95% RH
  • Dimensions
  • Approx. 100mm x 30mm
  • Sterilization
  • Autoclavable
  • Connector Type
  • Standard Male Connector
  • Response Time
  • <20 ms
  • Application
  • Compatible with Savina Ventilator
  • Material
  • Medical Grade Polycarbonate
 

Flow Sensor For Savina Trade Information

  • Minimum Order Quantity
  • 1 Piece
  • Payment Terms
  • Cash in Advance (CID)
  • Delivery Time
  • 7 Days
  • Main Domestic Market
  • All India
 

About Flow Sensor For Savina

Frequently Asked Questions

Q1. What is a Savina Flow Sensor used for?

It measures respiratory airflow in compatible Drger Savina ventilator systems and supports flow-related monitoring functions.

Q2. Is this flow sensor compatible with all Drger Savina ventilators?

Not necessarily. Compatibility depends on the specific Savina model, flow sensor configuration, and required part number.

Q3. Can this sensor be used as a replacement part?

Yes, provided its specifications match the ventilator's requirements and compatibility is confirmed.

Q4. Who can purchase this product?

Hospitals, ICU departments, biomedical engineers, ventilator maintenance providers, and medical equipment distributors.

Q5. Does the flow sensor require testing after installation?

Yes. Appropriate functional checks and any manufacturer-required calibration should be completed before the ventilator is returned to clinical use.



High-Performance Sensor for Medical Ventilators

This flow sensor is crafted to work seamlessly with Savina ventilators, using advanced differential pressure and thermal principles to provide accurate airflow measurement. Its robust build and wide operating conditions make it adaptable to diverse clinical settings. Reliable and responsive, it supports precise ventilation management and patient care.


Safe and Durable Medical-Grade Construction

Constructed from medical grade polycarbonate, the sensor is both sturdy and safe for repeated use in healthcare environments. Its autoclavable feature allows for efficient sterilization between uses, reducing the risk of cross-contamination and maintaining high standards of hygiene in medical facilities.


User-Friendly and Versatile Application

With its standard male connector and analog voltage output, this flow sensor offers straightforward installation with Savina ventilators. Its quick response time and wide temperature/humidity ranges ensure it performs consistently, supporting both routine and emergency medical situations.

FAQ's of Flow Sensor For Savina:


Q: How is the Flow Sensor for Savina installed with the ventilator?

A: The sensor features a standard male connector, enabling quick and secure attachment to compatible Savina ventilators. Its design ensures a stable fit without complex tools or procedures.

Q: What benefits does the medical-grade polycarbonate material provide?

A: Medical-grade polycarbonate offers excellent durability, impact resistance, and biocompatibility. This ensures the sensor withstands frequent sterilizations while maintaining safety for use with patients.

Q: When should the flow sensor be sterilized, and what is the recommended process?

A: It should be sterilized between patient uses to prevent cross-contamination. The sensor is autoclavable, allowing for safe and effective sterilization using standard autoclave protocols commonly found in hospitals.

Q: Where can this sensor be used, considering environmental conditions?

A: The sensor is suitable for clinical environments with operating temperatures from 0C to 60C and humidity levels from 0% to 95% RH, ensuring reliable performance in a wide array of hospital conditions.

Q: What is the maximum flow measurement capability of this sensor?

A: It accurately measures airflow rates from 0 to 80 liters per minute, making it ideal for respiratory support in adult and pediatric ventilation scenarios.

Q: How does the fast response time benefit ventilator performance?

A: With a response time under 20 ms, the sensor quickly detects changes in airflow, allowing the ventilator to adjust promptly and maintain precise ventilation, which is critical for patient safety and comfort.

Q: What is the advantage of the analog voltage output provided by this sensor?

A: The analog voltage output (0 to 5V) allows for straightforward integration and real-time airflow measurement, enabling ventilators to process and adjust settings efficiently for optimal respiratory support.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Oxygen Sensors Category

City Technology AO2 Oxygen Sensor Oxygen Monitoring Sensor for Compatible Medical Equipment

City Technology AO2 Oxygen Sensor Oxygen Monitoring Sensor for Compatible Medical Equipment

Price 3600 INR / Piece

Minimum Order Quantity : 1 Piece

Accuracy : 2% of reading

Output : Other

Theory : Other

Storage Temperature : 0C to +20C

Flow Sensor For GE Anesthesia

Flow Sensor For GE Anesthesia

Price 20000 INR / Piece

Minimum Order Quantity : 1 Piece

Accuracy : 2% full scale

Output : Other, Analog voltage

Theory : Other, Microbridge thermal transfer

Storage Temperature : 20C to 70C

Drager Babylog Flow Sensor

Drager Babylog Flow Sensor

Minimum Order Quantity : 1 Piece

Accuracy : 2% full scale

Output : Other, Analog

Theory : Other, Differential Pressure

Storage Temperature : 20C to 60C

GE Engstrom Flow Sensor

GE Engstrom Flow Sensor

Minimum Order Quantity : 1 Piece

Accuracy : 3% or better

Output : Other, Analog (proportional to flow rate)

Theory : Other, Measures flow using differential pressure across a restriction

Storage Temperature : 40C to +70C